Farm Pump Flow and Tank Filling Calculator

Your pump may produce enough water across a day, or a tank may carry you through a shortfall for now. Compare both with the water your farm needs today, then check whether the pump can keep up tomorrow.

Your daily water plan

Use the same supply point and day for the pump and demand figures.

Switching units converts valid water and flow entries.

1. What can the pump supply?

L/min

Use measured flow under your operating conditions.

h/day

Available run time, from 0 to 24 hours.

2. What does the farm need?

L

Water you can actually draw, not the tank's nominal label size.

L/day

Gross demand after crop-side irrigation losses; enter 0 for no demand.

Optional: water already stored and transfer loss

The conservative default starts with an empty tank and no extra loss after your entered flow measurement.

L

Default 0; cannot exceed usable capacity. Count it once today.

%

Default 0. Do not re-enter irrigation application loss already in demand.

Supply against demand

Today uses the water already in the tank once. The repeat-day check uses pump output alone.

Today's volume check

Enter your pump, tank and daily demand, then check supply.

A daily volume check cannot prove water is available at each peak hour. Verify measured flow, source yield, tank controls, pressure, and the timing of withdrawals before using it as a system design.

At the pump and tank

Will there be enough water through the day?

It is easy to look at a large tank and feel covered. Yet the useful question is how much water the pump can replace during the day—and how much is actually in the tank when the day begins.

This calculator checks those two amounts against a daily water demand. It gives one answer for today and a separate check for following days. That distinction matters when a tank can bridge a shortage once but the pump cannot refill it fast enough to keep doing so.

How to use the calculator

Step 1

Measure the pump's useful flow

Choose litres or US gallons, then enter the pump flow while it runs and the hours it can operate in a day. Use a field measurement at the intended pressure when available. If flow is measured before a known transfer loss, open the optional section and enter that loss.

Step 2

Match the tank and daily demand

Enter usable tank capacity and the gross water volume your farm must receive in one day. The tank starts empty in the default check. If it already holds usable water, enter that amount under the optional section; a tank's labeled capacity is not the same as water available now.

Step 3

Read both supply checks

The large result compares today's pump output plus current tank water with demand. Read the repeat-day line next: it compares demand with pump output alone. Use tank filling time to understand the storage scale, then check the actual hours when water will be drawn.

The daily balance, in plain numbers

A pump measured at 100 L/min and running for eight hours produces 48,000 L before any transfer loss. If the farm needs 40,000 L that day and the tank starts empty, the volume check shows an 8,000 L surplus. A usable 10,000 L tank takes 100 minutes to fill from empty at that flow, provided nothing is drawn while it fills.

Usable pump flow = measured flow × (1 − transfer loss ÷ 100)

Pump water per day = usable flow × 60 × operating hours

Available today = pump water per day + water in tank now

Today's balance = available today − daily demand

Repeat-day balance = pump water per day − daily demand

The tank's capacity sets the size of the buffer, but capacity alone does not add water to today's supply. Enter the water actually stored. The calculations keep full precision; displayed volumes are rounded for reading.

When the tank gets you through today, but not tomorrow

A useful warning

One good day can hide a continuing gap

Suppose that same 100 L/min pump has 10% transfer loss. At eight hours it supplies 43,200 L/day. If the tank holds 5,000 L now and demand is 45,000 L, there are 48,200 L available today: 3,200 L above today's demand.

Tomorrow's pump contribution is still only 43,200 L. Against 45,000 L/day, that is a 1,800 L/day repeat deficit. Unless another source refills the tank, the buffer shrinks. The empty-to-full fill time is about 111.11 minutes at 90 L/min useful flow.

Today+3,200 L
Repeat day−1,800 L/day

A tank buys time; it does not create daily water.

What a short day looks like

Now consider a pump delivering 20 US gal/min for six hours. It produces 7,200 US gal. A tank with 1,000 US gal of usable capacity contains only 500 US gal at the start, so today's available water is 7,700 US gal.

If demand is 8,000 US gal, the result is 300 US gal short today. The repeat-day pump deficit is 800 US gal/day. Entering the full 1,000-gallon tank capacity as though it were stored water would hide the immediate shortage.

What tank filling time and equivalents mean

Empty-to-full time divides usable tank capacity by effective pump flow. For a 1,000 US gal tank and 20 US gal/min useful flow, that is 50 minutes. The figure assumes the pump runs continuously and nobody draws water during filling. It is a fill-time check, not a promise about automatic cycling.

The page also divides daily demand by usable tank capacity. If demand is 8,000 US gal and usable capacity is 1,000 US gal, the result is eight full-tank equivalents. This helps you picture the volume, but it does not mean the pump will start exactly eight times. Control settings and the timing of withdrawals determine real cycles.

Keep the two kinds of water loss separate

Daily demand should be the water the farm needs supplied to its irrigation or use point. If a crop plan gives water needed at the roots, its application efficiency belongs in the step that converts that net need into gross demand. The Crop Water Requirement Calculator can make that estimate.

The optional transfer-loss field here concerns water lost between the measured pump flow and usable supply. Do not enter irrigation application loss in both places. If you measured flow at the tank inlet or final supply point, zero additional transfer loss is usually the relevant arithmetic setting.

Before relying on the answer

  • Check the pump under load. Actual flow can change with lift, pressure, filters and source level.
  • Check the tank's usable range. Dead storage and control levels may make nominal capacity larger than drawdown available to you.
  • Check the clock, not just the total. A pump that makes enough water by evening may still fail an early peak draw.
  • Check the source. A well or intake must be able to sustain the entered flow for the entered hours.

This calculator does not size pipes or pumps, model well recharge, predict the hour a tank empties, or decide legal withdrawal limits. For one irrigation zone's operating time after its water target is known, use the Irrigation Runtime Calculator.

Frequently asked questions

Does a full tank count as daily pump production?
No. Only the water already in the tank is added to today’s available volume, once. The repeat-day check uses pump production alone; a tank cannot replace a continuing pump shortfall without another refill source.
Should I enter net crop water need or water to supply?
Enter the gross volume that must reach the farm’s supply or irrigation system after any crop-side application loss. If a crop calculator gives net root-zone need, convert it to gross demand there first. The transfer-loss field here covers loss before water becomes usable.
What flow rate should I use?
Use measured flow at the operating conditions you expect, preferably at the tank inlet or delivery point. A pump nameplate rate may differ after lift, pressure, pipe friction or a falling source level.
What does zero transfer loss mean?
It means the entered flow is already usable at the supply point, or you are explicitly assuming no further transfer loss. It is not a claim that the irrigation system applies all water perfectly.
Does “covers today” guarantee water at the right hour?
No. It compares daily volumes only. A tank may empty during a peak withdrawal even when the day’s total supply is sufficient; pump and valve timing require a separate schedule.
What does tank filling time assume?
It is the empty-to-full time at the entered effective pump flow, with no water drawn while filling. Current tank water and daily pump operating hours do not change that isolated fill-time calculation.
Are full-tank equivalents actual pump cycles?
No. Demand divided by usable tank capacity is a volume comparison. Real starts and refills depend on tank controls and when water is withdrawn.
Can I use this to size a well or prove the pump will run all day?
No. The calculation takes the entered flow and operating hours as available. It does not test well recharge, pressure, head, motor limits, water quality or withdrawal rules.